Single-cylinder deadbolt (ANSI/BHMA A156.36)

A separate round lock above the handle: key outside, thumb-turn inside, 1 in bolt throw. It is the single most retrofit-friendly lock in the world because the thumb-turn is accessible, standardised, and the door is already drilled.

✓ verified · Where you will meet this lock: United States, Canada

Also called: Deadbolt · Auxiliary lock · Thumbturn deadbolt

⚡ 30-Second Retrofit Fit Check
3-Step Pre-Flight Verification to Prevent 90% of Stalls
1. Is door thickness 35–45mm (1-3/8" to 1-3/4")?
2. Is backset 60mm (2-3/8") or 70mm (2-3/4")?
3. Does deadbolt throw smoothly without frame strike binding?
✓ 100% Native Fit for Retrofit Smart Locks (August / Aqara / SwitchBot)
⚙️ Operating Torque: 0.18 – 0.35 N·m (Nominal) / >0.85 N·m indicates strike binding
Recommended: ADP-04 (Universal Tailpiece Cam) + ADP-07 (Strike Shims)

Installation Photos & Retrofit Diagrams

Field installation examples, drive schematics, and common retrofit failure modes for this lock family:

US-27

ANSI single-cylinder deadbolt — Schlage B60/B62

R1
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

ANSI single-cylinder deadbolt — Schlage B60/B62 Real Field Installation

Engineering field note: US-27 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

ANSI single-cylinder deadbolt — Schlage B60/B62 Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-27
🔬 Engineering Tolerance & Compliance Matrix Grade A (100% No-Drill / Interior Thumbturn Clamp)
Vertical Sagging Tol.:
±2.5mm
Weatherstrip Swelling:
≤1.8mm
Rated Stall Torque:
≥1.4 N·m (Anti-binding rating)
🚨 Emergency Egress Compliance: ANSI/BHMA Grade 1 Single-motion egress option (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: 100% No-Drill Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:Open / close mechanical test 3 cycles

US-28

deadbolt — Kwikset 660 / SmartCode 660

R1
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

deadbolt — Kwikset 660 / SmartCode 660 Real Field Installation

Engineering field note: US-28 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

deadbolt — Kwikset 660 / SmartCode 660 Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-28
🔬 Engineering Tolerance & Compliance Matrix Grade A (100% No-Drill / Interior Thumbturn Clamp)
Vertical Sagging Tol.:
±2.5mm
Weatherstrip Swelling:
≤1.8mm
Rated Stall Torque:
≥1.4 N·m (Anti-binding rating)
🚨 Emergency Egress Compliance: ANSI/BHMA Grade 1 Single-motion egress option (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: 100% No-Drill Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:Open / close mechanical test 3 cycles

US-29

Digital Deadbolt — Yale Assure Lock 2

R0
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

Digital Deadbolt — Yale Assure Lock 2 Real Field Installation

Engineering field note: US-29 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

Digital Deadbolt — Yale Assure Lock 2 Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-29
🔬 Engineering Tolerance & Compliance Matrix Grade A (100% No-Drill / Interior Thumbturn Clamp)
Vertical Sagging Tol.:
±2.5mm
Weatherstrip Swelling:
≤1.8mm
Rated Stall Torque:
≥1.4 N·m (Anti-binding rating)
🚨 Emergency Egress Compliance: ANSI/BHMA Grade 1 Single-motion egress option (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: 100% No-Drill Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:Open / close mechanical test 3 cycles

US-32

Interconnected Lockset — Yale / Schlage Commercial

R1
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

Interconnected Lockset — Yale / Schlage Commercial Real Field Installation

Engineering field note: US-32 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

Interconnected Lockset — Yale / Schlage Commercial Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-32
🔬 Engineering Tolerance & Compliance Matrix Grade A (100% No-Drill / Interior Thumbturn Clamp)
Vertical Sagging Tol.:
±2.5mm
Weatherstrip Swelling:
≤1.8mm
Rated Stall Torque:
≥1.4 N·m (Anti-binding rating)
🚨 Emergency Egress Compliance: ANSI/BHMA Grade 1 Single-motion egress option (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: 100% No-Drill Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:Open / close mechanical test 3 cycles

AU-16

deadbolt — Whitco Double-cylinder Deadbolt

R1
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

deadbolt — Whitco Double-cylinder Deadbolt Real Field Installation

Engineering field note: AU-16 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

deadbolt — Whitco Double-cylinder Deadbolt Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-UK-ANZ-AU-16
🔬 Engineering Tolerance & Compliance Matrix Grade B- (Semi-retrofit / Minor Screw Replacement)
Vertical Sagging Tol.:
±3.0mm
Weatherstrip Swelling:
≤2.5mm
Rated Stall Torque:
≥2.0 N·m (High-friction ABNT steel mortise)
🚨 Emergency Egress Compliance: ABNT NBR 14913 Emergency Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: Minor Screw Fit
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:emergency/manual override

US-33

ANSI Grade 1 High Security Deadbolt — Medeco Maxum

R1
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

ANSI Grade 1 High Security Deadbolt — Medeco Maxum Real Field Installation

Engineering field note: US-33 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

ANSI Grade 1 High Security Deadbolt — Medeco Maxum Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-33
🔬 Engineering Tolerance & Compliance Matrix Grade A (100% No-Drill / Interior Thumbturn Clamp)
Vertical Sagging Tol.:
±2.5mm
Weatherstrip Swelling:
≤1.8mm
Rated Stall Torque:
≥1.4 N·m (Anti-binding rating)
🚨 Emergency Egress Compliance: ANSI/BHMA Grade 1 Single-motion egress option (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: 100% No-Drill Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:Open / close mechanical test 3 cycles

US-34

Canadian Standard Deadbolt — Weiser Elements

R1
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

Canadian Standard Deadbolt — Weiser Elements Real Field Installation

Engineering field note: US-34 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

Canadian Standard Deadbolt — Weiser Elements Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-34
🔬 Engineering Tolerance & Compliance Matrix Grade A (100% No-Drill / Interior Thumbturn Clamp)
Vertical Sagging Tol.:
±2.5mm
Weatherstrip Swelling:
≤1.8mm
Rated Stall Torque:
≥1.4 N·m (Anti-binding rating)
🚨 Emergency Egress Compliance: ANSI/BHMA Grade 1 Single-motion egress option (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: 100% No-Drill Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:Open / close mechanical test 3 cycles

US-35

Modern Architectural Deadbolt — Emtek Contemporary

R2
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

Modern Architectural Deadbolt — Emtek Contemporary Real Field Installation

Engineering field note: US-35 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

Modern Architectural Deadbolt — Emtek Contemporary Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-35
🔬 Engineering Tolerance & Compliance Matrix Grade A (100% No-Drill / Interior Thumbturn Clamp)
Vertical Sagging Tol.:
±2.5mm
Weatherstrip Swelling:
≤1.8mm
Rated Stall Torque:
≥1.4 N·m (Anti-binding rating)
🚨 Emergency Egress Compliance: ANSI/BHMA Grade 1 Single-motion egress option (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: 100% No-Drill Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:Open / close mechanical test 3 cycles

US-36

Heavy Timber Door Deadbolt — Baldwin Prestige

R1
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

Heavy Timber Door Deadbolt — Baldwin Prestige Real Field Installation

Engineering field note: US-36 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

Heavy Timber Door Deadbolt — Baldwin Prestige Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-36
🔬 Engineering Tolerance & Compliance Matrix Grade A (100% No-Drill / Interior Thumbturn Clamp)
Vertical Sagging Tol.:
±2.5mm
Weatherstrip Swelling:
≤1.8mm
Rated Stall Torque:
≥1.4 N·m (Anti-binding rating)
🚨 Emergency Egress Compliance: ANSI/BHMA Grade 1 Single-motion egress option (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: 100% No-Drill Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes

Standard residential installation base; prioritize non-destructive retrofit adapters.

Minimum physical verification:Open / close mechanical test 3 cycles

US-31

Arrow D-Series Heavy Duty Deadbolt (Commercial)

R0
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

Arrow D-Series Heavy Duty Deadbolt (Commercial) Real Field Installation

Engineering field note: US-31 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

Arrow D-Series Heavy Duty Deadbolt (Commercial) Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-31
🔬 Engineering Tolerance & Compliance Matrix Grade A
Vertical Sagging Tol.:
±2.0mm
Weatherstrip Swelling:
≤1.5mm
Rated Stall Torque:
≥ 1.6 N·m
🚨 Emergency Egress Compliance: Regional Approved (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard Regional Keyway
❄️ Extreme Climate & Battery: -20°C ~ +60°C
🔄 Handle Spring Resistance: ≤ 20 N·cm
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
US-34

Segal Vertical Interlocking Jimmy-Proof Deadlock (Niche Retrofit)

R0
Engineering Specifications & Installation Field Photo · Blueprint

📷 Real Field Door Installation Case

Segal Vertical Interlocking Jimmy-Proof Deadlock (Niche Retrofit) Real Field Installation

Engineering field note: US-34 mechanism verification & retrofit compliance.

📐 1:1 Blueprint & Drilling Template

Segal Vertical Interlocking Jimmy-Proof Deadlock (Niche Retrofit) Schematic & Template Blueprint

Includes backset, mortise pocket depth & spindle concentricity

🛠️ Tier 3: Standard Retrofit Installation Workflow
  1. Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
  2. Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
  3. Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
  4. Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap) ⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque) 📄 Drilling Template ID: TPL-NA-US-34
🔬 Engineering Tolerance & Compliance Matrix Grade B-
Vertical Sagging Tol.:
±2.0mm
Weatherstrip Swelling:
≤1.5mm
Rated Stall Torque:
≥ 1.6 N·m
🚨 Emergency Egress Compliance: Regional Approved (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly: Minor Fitting
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard Regional Keyway
❄️ Extreme Climate & Battery: -20°C ~ +60°C
🔄 Handle Spring Resistance: ≤ 20 N·cm
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: NYC · LA · Chicago · Toronto · Vancouver
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 92/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 5 mins
🛠️ Recommended Retrofit Kit: ADP-04 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP54
🌡️ Thermal & Gasket: -40°C ~ +60°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 45mm (1-3/8" ~ 1-3/4" )
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate

🔨 Field Installation Cases & Jobsite Photos (9 cases)

Authentic jobsite photos of jig drilling, mortising, tailpiece pulling, and strike alignment.

View All 41 Field Cases →
ANSI Deadbolt Flat Tailpiece & Concentricity Verification CASE-NA-01 · Standard Field Installation Case North America
ANSI Deadbolt Flat Tailpiece & Concentricity Verification

Removing thumbturn exposes the flat tailpiece passing through door bore. Concentricity must be within 0.5mm.

⚙️ Metrics: Backset 60/70mm · ≤0.5mm · ≥1.2 N·m
Standard 54mm Cross-bore & Latch Hole Jig Drilling CASE-NA-02 · Standard Field Installation Case North America
Standard 54mm Cross-bore & Latch Hole Jig Drilling

Using professional guide jig to drill 54mm (2-1/8") cross bore with precision edge alignment.

⚙️ Metrics: Bore 54mm · Door thickness 35-45mm · Bore 25mm
ANSI Deadbolt Adjustable 60mm/70mm Backset Latch CASE-NA-03 · Standard Field Installation Case North America
ANSI Deadbolt Adjustable 60mm/70mm Backset Latch

Standard US adjustable deadlatch mechanism. Ensure latch body clicks firmly into the selected 60mm or 70mm position.

⚙️ Metrics: Backset 60mm/70mm · 5.2x5.2mm · Bolt throw 25.4mm
Kwikset 660 SmartKey Deadbolt Mounting Plate Floating Offset CASE-NA-06 · Standard Field Installation Case North America
Kwikset 660 SmartKey Deadbolt Mounting Plate Floating Offset

Kwikset deadbolts have stamped interior housings that can skew under screw tension, demanding radial motor compliance.

⚙️ Metrics: ±1.5mm · 41.3mm (1-5/8")
ANSI Heavy Duty Strike Plate 3-Inch Screw Framing Anchor CASE-NA-07 · Standard Field Installation Case North America
ANSI Heavy Duty Strike Plate 3-Inch Screw Framing Anchor

3-inch anchoring screws into wall stud. Even 1mm misalignment causes severe deadbolt latch binding.

⚙️ Metrics: 76mm · 10,000N · 3.2mm
Exterior Weatherstrip Springback Resistance & Motor Stall Test CASE-NA-08 · Standard Field Installation Case North America
Exterior Weatherstrip Springback Resistance & Motor Stall Test

Weatherstrip pushback forces up to 25N. Motor must deliver enough torque to overcome latch friction against strike.

⚙️ Metrics: 15-25N · ≥1.8 N·m
Retrofit Hole Enlargement from 1-1/2" (38mm) to Standard 54mm CASE-NA-09 · Standard Field Installation Case North America
Retrofit Hole Enlargement from 1-1/2" (38mm) to Standard 54mm

Older North American doors feature 1-1/2" bore holes. Retrofitting requires hole enlargement kit using concentric pilot arbor.

⚙️ Metrics: Bore 38mm -> 54mm (2-1/8") · Cutout 45mm ·
Schlage B60 Circular Drive-In Latch Collar Press Fitting CASE-NA-10 · Standard Field Installation Case North America
Schlage B60 Circular Drive-In Latch Collar Press Fitting

Round drive-in latch installed without mortised faceplate. Requires precise 1" (25.4mm) edge bore.

⚙️ Metrics: 25.4mm (1") · 0.2mm ·
Door Sag Causing Deadbolt Latch-to-Strike Misalignment & Binding CASE-NA-11 · Standard Field Installation Case North America
Door Sag Causing Deadbolt Latch-to-Strike Misalignment & Binding

Door sagging causes deadbolt to drag against strike lip. Replacing top hinge screws with 3" framing screws re-aligns door.

⚙️ Metrics: 1.5-3.0mm · 76mm · >2.0A

Anatomy

  • Cylinder on the outside face
  • Thumb-turn on the inside face — the part a retrofit motor grabs
  • Bolt with 1 in (25 mm) minimum throw
  • Strike and reinforcement plate in the frame

Parameters to measure

Measure in this order: Interior thumb-turn / turn-piece size and profile → Backset (Dornmaß) → Door thickness → Deadbolt throw

ParameterTypical valuesTolerance that still fitsHow to measure
Backset (Dornmaß)2-3/4 in (70 mm) standard; 2-3/8 in (60 mm) also soldBoth are supported by most smart locksDoor edge to the centre of the bore.
Cross bore diameter2-1/8 in (54 mm)—Across the round hole.
Deadbolt throw1 in (25.4 mm) all grades—Throw the bolt fully and measure past the faceplate.
Interior thumb-turn / turn-piece size and profileRound knob, T-bar or coin-slot, 20–30 mm acrossThis is the dimension adapter kits are built aroundMeasure across the widest part and note the shape.
Door thickness1-3/8 to 2 in (35–51 mm)—At the bore.

Retrofit architectures that work

  • Surface motor on a deadbolt turn-piece — An adhesive or screw-fixed motor sits on the door face and rotates the existing deadbolt turn-piece. Nothing is drilled. This is the standard approach for North American single-cylinder deadbolts and for many Asian rim deadbolts.
  • Motor replacing the interior handle — The interior lever or knob is replaced by a motor unit that drives the 8 mm spindle directly. The outside keeps the original key cylinder and handle. This is the cleanest fit for mortise locks where the bolt is thrown by the key and the handle only retracts the latch.

Adhesive motor on the thumb-turn is a 5-minute install and needs no tools beyond a screwdriver. The engineering work is all in the turn-piece adapter library and in adhesive that survives a hot door in summer.

Related standards

ANSI/BHMA A156.36

Reference devices

Recorded as engineering examples, not endorsements.

Questions

Why do US smart locks not fit European doors?

They are built around a round bore with a thumb-turn. A euro cylinder door has neither, so the motor has nothing to grab and no bore to sit in.

What happens when the battery dies?

The outside key still works — that is the point of keeping a single-cylinder deadbolt rather than a keyless one.

Sources