5-lever mortice deadlock (BS 3621)
A lever lock keyed from both sides, with no cylinder at all: the key moves the levers directly through a keyhole in the faceplate. BS 3621 certification requires at least five levers, hardplates and a 20 mm bolt throw. Retrofit is hard here — there is no cylinder and no spindle to drive.
✓ verified · Where you will meet this lock: United Kingdom, Ireland
Also called: 5 lever deadlock · Chubb lock · British Standard deadlock
Installation Photos & Retrofit Diagrams
Field installation examples, drive schematics, and common retrofit failure modes for this lock family:
⌖ Mortise Lock Cases
5 models
📷 Real Field Door Installation Case
Engineering field note: EU-24 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-EU-24
🔬 Engineering Tolerance & Compliance Matrix
Grade B- (Semi-retrofit / Minor Screw Replacement)
Vertical Sagging Tol.:
±3.0mm
Weatherstrip Swelling:
≤2.5mm
Rated Stall Torque:
≥2.0 N·m (High-friction ABNT steel mortise)
🚨 Emergency Egress Compliance:
ABNT NBR 14913 Emergency Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Minor Screw Fit
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes
Standard residential installation base; prioritize non-destructive retrofit adapters.
Minimum physical verification:Open / close mechanical test 3 cycles
📷 Real Field Door Installation Case
Engineering field note: EU-25 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-EU-25
🔬 Engineering Tolerance & Compliance Matrix
Grade B- (Semi-retrofit / Minor Screw Replacement)
Vertical Sagging Tol.:
±3.0mm
Weatherstrip Swelling:
≤2.5mm
Rated Stall Torque:
≥2.0 N·m (High-friction ABNT steel mortise)
🚨 Emergency Egress Compliance:
ABNT NBR 14913 Emergency Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Minor Screw Fit
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes
Standard residential installation base; prioritize non-destructive retrofit adapters.
Minimum physical verification:Open / close mechanical test 3 cycles
📷 Real Field Door Installation Case
Engineering field note: UK-42 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-UK-42
🔬 Engineering Tolerance & Compliance Matrix
Grade B- (Semi-retrofit / Minor Screw Replacement)
Vertical Sagging Tol.:
±3.0mm
Weatherstrip Swelling:
≤2.5mm
Rated Stall Torque:
≥2.0 N·m (High-friction ABNT steel mortise)
🚨 Emergency Egress Compliance:
ABNT NBR 14913 Emergency Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Minor Screw Fit
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes
Standard residential installation base; prioritize non-destructive retrofit adapters.
Minimum physical verification:Open / close mechanical test 3 cycles
📷 Real Field Door Installation Case
Engineering field note: AU-40 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-AU-40
🔬 Engineering Tolerance & Compliance Matrix
Grade A
Vertical Sagging Tol.:
±2.0mm
Weatherstrip Swelling:
≤1.5mm
Rated Stall Torque:
≥ 1.6 N·m
🚨 Emergency Egress Compliance:
Regional Approved (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard Regional Keyway
❄️ Extreme Climate & Battery: -20°C ~ +60°C
🔄 Handle Spring Resistance: ≤ 20 N·cm
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
📷 Real Field Door Installation Case
Engineering field note: AF-02 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-AF-SA-AF-02
🔬 Engineering Tolerance & Compliance Matrix
Grade A-
Vertical Sagging Tol.:
±3.5mm
Weatherstrip Swelling:
≤3.0mm
Rated Stall Torque:
≥2.0 N·m
🚨 Emergency Egress Compliance:
SASO / EN 179 Panic Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Non-destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: Johannesburg · Cape Town · Lagos
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 72/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 12 mins
🛠️ Recommended Retrofit Kit: ADP-10 + ADP-08
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🚪 Door Thickness & Fasteners: Nominal Door: 40mm ~ 50mm
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⌖ Specialty & High-Security
1 models
📷 Real Field Door Installation Case
Engineering field note: AU-41 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-AU-41
🔬 Engineering Tolerance & Compliance Matrix
Grade B-
Vertical Sagging Tol.:
±2.0mm
Weatherstrip Swelling:
≤1.5mm
Rated Stall Torque:
≥ 1.6 N·m
🚨 Emergency Egress Compliance:
Regional Approved (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Minor Fitting
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard Regional Keyway
❄️ Extreme Climate & Battery: -20°C ~ +60°C
🔄 Handle Spring Resistance: ≤ 20 N·cm
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
🔨 Field Installation Cases & Jobsite Photos (2 cases)
Authentic jobsite photos of jig drilling, mortising, tailpiece pulling, and strike alignment.
View All 41 Field Cases →
CASE-EU-05 · Standard Field Installation Case
Continental Europe
BS 3621 British Standard 5-Lever Mortice Deadlock Fitting
British Standard BS 3621 5-lever deadlock. Thick case with anti-drill plates and curtain mechanism.
⚙️ Metrics: Backset 44mm/57mm (2.5"/3") · Bolt throw 20mm · BS 3621 Engraving
CASE-ANZ-08 · Standard Field Installation Case
Australia & UK
UK Union 3-Lever Interior Sashlock Case Replacement & Prep
Victorian UK 3-lever sashlock. Historic door requires brass conversion escutcheon for modern drive fitting.
⚙️ Metrics: Backset 44mm/57mm · PZ 57mm · Lever count 3 Levers
Anatomy
- Lever stack — the gate pattern that gives the key its differs
- Deadbolt only, no spring latch
- Faceplate with a keyhole on each side
- Kitemark stamp on the faceplate when certified
Parameters to measure
Measure in this order: Lever count → Lock case width × height × depth → Backset (Dornmaß) → Deadbolt throw
| Parameter | Typical values | Tolerance that still fits | How to measure |
| Lock case width × height × depth | Case sizes commonly 76 mm or 64 mm (3 in / 2.5 in nominal) | — | Measure the case width across the door edge. |
| Backset (Dornmaß) | 44 mm (76 mm case) or 57 mm, varies by maker | — | Door edge to the centre of the keyhole. |
| Lever count | 5 for BS 3621; 2 or 3 on older and interior locks | — | Count through the keyhole or from the case edge. |
| Deadbolt throw | 20 mm minimum for BS 3621 | — | Key the bolt fully out and measure how far it projects past the faceplate. |
|---|
Retrofit architectures that work
There is no clean retrofit path for this family. See the note below.
There is no clean retrofit for a lever lock. The honest options are: (1) replace the case with a euro-cylinder mortise deadlock, which needs a new door prep and, on a fire door, a certified doorset; (2) keep the lever lock and add a separate smart deadbolt above or below; (3) leave it alone — a BS 3621 lever lock is already a good lock. Never design a retrofit that leaves the door unable to be opened by hand from inside.
Related standards
BS 3621 · BS 8621 · BS 10621
Questions
How do I know if my lock is really BS 3621?
Look for the Kitemark and the words BS 3621 stamped on the faceplate — the strip visible on the door edge when the door is open. Some 5-lever locks are not certified, and a 3-lever lock can never be.
What is the difference between BS 3621 and BS 8621?
Same attack resistance. BS 3621 needs a key on both sides; BS 8621 has a thumb-turn or push-pad inside for keyless escape. BS 10621 locks from outside only.