Australian deadlatch and deadlock
A surface deadlatch with a key outside and a knob or slide inside, plus a separate deadlock on many doors. Mechanically close to the UK nightlatch but with its own case geometry and a strong local brand ecosystem.
⚠ needs review · Where you will meet this lock: Australia, New Zealand
Also called: Deadlatch · Lockwood-type latch · Night latch (AU)
Installation Photos & Retrofit Diagrams
Field installation examples, drive schematics, and common retrofit failure modes for this lock family:
📷 Real Field Door Installation Case
Engineering field note: AU-11 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-AU-11
🔬 Engineering Tolerance & Compliance Matrix
Grade B- (Semi-retrofit / Minor Screw Replacement)
Vertical Sagging Tol.:
±3.0mm
Weatherstrip Swelling:
≤2.5mm
Rated Stall Torque:
≥2.0 N·m (High-friction ABNT steel mortise)
🚨 Emergency Egress Compliance:
ABNT NBR 14913 Emergency Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Minor Screw Fit
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes
Standard residential installation base; prioritize non-destructive retrofit adapters.
Minimum physical verification:Open / close mechanical test 3 cycles
📷 Real Field Door Installation Case
Engineering field note: AU-13 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-AU-13
🔬 Engineering Tolerance & Compliance Matrix
Grade B- (Semi-retrofit / Minor Screw Replacement)
Vertical Sagging Tol.:
±3.0mm
Weatherstrip Swelling:
≤2.5mm
Rated Stall Torque:
≥2.0 N·m (High-friction ABNT steel mortise)
🚨 Emergency Egress Compliance:
ABNT NBR 14913 Emergency Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Minor Screw Fit
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes
Standard residential installation base; prioritize non-destructive retrofit adapters.
Minimum physical verification:Open / close mechanical test 3 cycles
📷 Real Field Door Installation Case
Engineering field note: AU-17 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-AU-17
🔬 Engineering Tolerance & Compliance Matrix
Grade B- (Semi-retrofit / Minor Screw Replacement)
Vertical Sagging Tol.:
±3.0mm
Weatherstrip Swelling:
≤2.5mm
Rated Stall Torque:
≥2.0 N·m (High-friction ABNT steel mortise)
🚨 Emergency Egress Compliance:
ABNT NBR 14913 Emergency Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Minor Screw Fit
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes
Standard residential installation base; prioritize non-destructive retrofit adapters.
Minimum physical verification:Open / close mechanical test 3 cycles
📷 Real Field Door Installation Case
Engineering field note: AU-12 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-AU-12
🔬 Engineering Tolerance & Compliance Matrix
Grade B- (Semi-retrofit / Minor Screw Replacement)
Vertical Sagging Tol.:
±3.0mm
Weatherstrip Swelling:
≤2.5mm
Rated Stall Torque:
≥2.0 N·m (High-friction ABNT steel mortise)
🚨 Emergency Egress Compliance:
ABNT NBR 14913 Emergency Safe (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Minor Screw Fit
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard regional keyway profile
❄️ Extreme Climate & Battery: -20°C low-temperature lithium cell recommended; alkaline cells derate by 40%
🔄 Handle Spring Resistance: Nominal handle return spring resistance 0.35 - 0.60 N·m
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
⚙️ Retrofit Engineering & Resistance Notes
Standard residential installation base; prioritize non-destructive retrofit adapters.
Minimum physical verification:Open / close mechanical test 3 cycles
📷 Real Field Door Installation Case
Engineering field note: AU-39 mechanism verification & retrofit compliance.
📐 1:1 Blueprint & Drilling Template
Includes backset, mortise pocket depth & spindle concentricity
🛠️ Tier 3: Standard Retrofit Installation Workflow
- Step 1: Baseline Hardware Check — Verify backset, door thickness, and strike depth
- Step 2: Baseplate Alignment — Secure mounting bracket, control concentricity (≤0.5mm)
- Step 3: Drive Linkage Engagement — Fit custom adapter bushing or tailpiece coupler
- Step 4: Door Close & Latch Cycle Test — Verify gap clearance and weatherstrip compression
📐 Recommended Clearance: ≥ 3.0mm (Door to Frame Gap)
⚡ Required Stall Torque: ≥ 1.2 N·m (Motor torque)
📄 Drilling Template ID: TPL-UK-ANZ-AU-39
🔬 Engineering Tolerance & Compliance Matrix
Grade A
Vertical Sagging Tol.:
±2.0mm
Weatherstrip Swelling:
≤1.5mm
Rated Stall Torque:
≥ 1.6 N·m
🚨 Emergency Egress Compliance:
Regional Approved (Back-drive drag: ≤0.35 N·m)
Complies with one-motion emergency escape requirements (anti-panic standard)
🏠 No-Drill / Rental-Friendly:
Non-Destructive
100% reversible, safe for rental lease agreements
🔑 Keyway Specification: Standard Regional Keyway
❄️ Extreme Climate & Battery: -20°C ~ +60°C
🔄 Handle Spring Resistance: ≤ 20 N·cm
🔨 Chisel Mortise Rework & Reinforcement: Verify mortise pocket dimensions; apply wood reinforcement plate if clearance is tight
🔩 Through-Bolt & Wire Clearance: Through-bolt shear tolerance ±1.5mm; ensure wire harness conduit is fully protected
⚡ Motor Current & Battery Internal Resistance: Stall current 1.8A max; internal battery resistance threshold <120mΩ
🛡️ Security & Insurance Rating: Certified attack-resistant security standard
🧲 Door Sensor Gap & Metal Shielding: Magnetic gap threshold ≤15mm; anti-ferromagnetic shielding bracket required on steel doors
🏙️ Metropolitan Distribution: London · Sydney · Melbourne · Manchester · Brisbane
⚙️ Gearbox Ratio & Back-Drive Torque: Recommended gear reduction ratio 120:1 to 180:1; planetary metal gearbox
📏 Shear Line Clearance & Depth: Clearance ≤1.0mm; thumbturn adapter recessed 5mm, dual pinch travel 2.5mm
🎯 Nuki Retrofit & ICP Profile: ★ Fit Score: 84/100 · Urban condo tenants & apartment owners
🔑 Tenant Zero-Damage Grade: Grade A- (No-drill cylinder clamp & slim gate safe) · Est. Install: 8 mins
🛠️ Recommended Retrofit Kit: ADP-05 + ADP-07
☀️ Salt Spray & Weatherproofing: ASTM B117 / EN 1670 Grade 4 Corrosion Resistance · IP55
🌡️ Thermal & Gasket: +55°C · Flame-retardant anti-fungal EPDM silicone weatherseal gasket
🔄 Multipoint Kinematics & Torque: Lift Angle: 45° Upward handle stroke · Drive Torque: Drive resistance 0.35 - 0.60 N·m
🔧 Hardware Vendors & Tuning: Winkhaus autoLock, GU-Secury, KFV/Siegenia · Adjust eccentric strike plate cams using hex key to reduce latch binding
🚪 Door Thickness & Fasteners: Nominal Door: 35mm ~ 50mm ()
🔩 Spindle & Bolt Spec: Spindle: 8mm square spindle bar · Bolts: M5 through-bolts cut-to-length based on door thickness
🛡️ Reinforcement: Architectural stainless steel reinforcement escutcheon plate
🔨 Field Installation Cases & Jobsite Photos (5 cases)
Authentic jobsite photos of jig drilling, mortising, tailpiece pulling, and strike alignment.
View All 41 Field Cases →
CASE-ANZ-01 · Standard Field Installation Case
Australia & UK
Lockwood 001 Deadlatch Mounting Casing & Template Fit
Field mounting of Lockwood 001 steel casing onto timber door guided by original paper drilling template.
⚙️ Metrics: Backset 60mm · Auxiliary bolt engagement 6mm · Thumbturn diameter 42mm
CASE-ANZ-02 · Standard Field Installation Case
Australia & UK
Lockwood 001 Inside Turn Knob LockAlert Visual Window
Signature teardrop turn knob with dual color LockAlert indicator. Retrofit motor requires specialized oval clamp.
⚙️ Metrics: Teardrop thumbturn major axis 48mm · minor axis 34mm · Torque 0.6 N·m
CASE-ANZ-03 · Standard Field Installation Case
Australia & UK
Lockwood 355 Dual Deadlocking Latch & Strike Interface
Heavy duty interlocking deadlatch. Claw bolt hooks into frame box to prevent jemmy attack.
⚙️ Metrics: Pry resistance ≥10kN · Strike margin ±2mm · Door gap 3-5mm
CASE-ANZ-06 · Standard Field Installation Case
Australia & UK
Lockwood 001 Deadlocking Failure: Auxiliary Pin Not Depressed
Critical deadlatch flaw: If auxiliary pin enters strike cavity instead of being depressed by strike rim, lock remains vulnerable.
⚙️ Metrics: Door gap must be ≤3.5mm · Deadlatch pin travel ≥5mm · Shim alignment
CASE-ANZ-07 · Standard Field Installation Case
Australia & UK
Lockwood 001 Rim Cylinder 32mm Hole Through-Bore & Tail Extension
Single 32mm cross bore for external cylinder. Doors thicker than 45mm require lengthened drive connecting bar.
⚙️ Metrics: Bore 32mm (1-1/4") · Door 30-45mm (Standard) / 45-60mm (Extended pin)
Anatomy
- Surface case with a spring deadlatch
- Rim cylinder through the door face
- Inside knob, slide or snib
- Optional separate deadlock below
Parameters to measure
Measure in this order: Lock case width × height × depth → Backset (Dornmaß) → Door thickness
| Parameter | Typical values | Tolerance that still fits | How to measure |
| Lock case width × height × depth | Survey locally — cases vary widely | — | Width and height of the surface case. |
| Backset (Dornmaß) | 60 mm common | — | Door edge to the cylinder centre. |
| Door thickness | 35–45 mm | — | At the cylinder. |
|---|
Retrofit architectures that work
- Motor on a rim (surface-mounted) lock — A motor unit is fixed to the surface-mounted rim lock case or to its knob, driving the latch or the deadbolt. Common on UK nightlatches and on Asian surface-mounted deadlocks.
- Surface motor on a deadbolt turn-piece — An adhesive or screw-fixed motor sits on the door face and rotates the existing deadbolt turn-piece. Nothing is drilled. This is the standard approach for North American single-cylinder deadbolts and for many Asian rim deadbolts.
- Motor replacing the interior handle — The interior lever or knob is replaced by a motor unit that drives the 8 mm spindle directly. The outside keeps the original key cylinder and handle. This is the cleanest fit for mortise locks where the bolt is thrown by the key and the handle only retracts the latch.
The inside control is often a slide or a snib rather than a rotatable knob, which no clamp adapter handles. Design an adapter that pulls, not just one that turns.
Related standards
AS 4174 (designation to be confirmed)
Reference devices
Recorded as engineering examples, not endorsements.
Questions
Is a deadlatch secure on its own?
A deadlocked deadlatch resists slipping, but most Australian insurers still expect a keyed deadlock on an external timber door.